Validasi Metode Penetapan Kadar Besi (Fe) dalam Telur Bebek menggunakan Spektrofotometri Serapan Atom (SSA)
DOI:
https://doi.org/10.59603/niantanasikka.v3i2.770Keywords:
duck, eggs, Iron, (AAS), ValidationAbstract
Iron (Fe) is an essential mineral that plays a crucial role in hemoglobin formation and various biological processes in the body. Duck eggs are known to contain a relatively high iron content, making it important to determine their iron levels using an accurate and reliable analytical method. This study aimed to validate the Atomic Absorption Spectrophotometry (AAS) method for determining iron content in duck eggs available in the Banjarbaru market, South Kalimantan. Duck egg samples were analyzed using a wet digestion method before measurement with AAS at a wavelength of 248.3 nm. The validated method parameters included linearity, limit of detection (LOD), limit of quantification (LOQ), precision, and accuracy. The results showed that the calibration curve had a correlation coefficient (r) of 0.9994 and a determination coefficient (R²) of 0.9988, indicating excellent linearity in the range of 0.0–10 ppm. The obtained LOD and LOQ values were 0.08 ppm and 0.27 ppm, respectively. Precision was demonstrated by an RSD of 7,01% for repeatability and 6.94% for intermediate precision, meeting the acceptance criteria. The accuracy of the method, indicated by an average % recovery of 98,40% ± 0,84, was also within the acceptable range (80–110%). Therefore, the validated AAS method in this study can be used as an accurate and reliable approach for analyzing iron content in duck eggs.
References
Aprilia, A.C. (2018). Validasi Metode Penentuan Nilai Kalori Batu Bara Menggunakan Bom Kalorimeter di Balai Pengujian dan Identifikasi Barang Tipe A Jakarta. Laporan Akhir Studi. Fakultas Matematika dan Ilmu Pengetahuan Alam. Universitas Islam Indonesia, Yogyakarta.
Astuti, R. (2019). Kandungan gizi dan manfaat telur bebek bagi kesehatan. Jurnal Pangan dan Gizi, 12(1), 45-52.
BSN. (2017). SNI ISO/IEC 17025 “Persyaratan Umum Kompetensi Laboratorium Pengujian dan Laboratorium Kalibrasi”. Badan Standarisasi Nasional. Jakarta.
Chaiyasit, W., Brannan, R., Chareonsuk, D., & Chanasattru, W. (2019). Properties of chicken and duck egg albumens. Brazilian Journal of Poultry Science, 21(1), 19.
Dedi Fardiaz, dkk. (2023). Kimia Pangan (Edisi 3, Hal 5.34). Tanggerang Selatan: Universitas Terbuka.
Djuhariningrum, T., Sarip, U., & Rosiana, I. (2014). Uji validasi metode analisis XRF untuk unsur-unsur Cu dan Th dalam SRM di laboratorium eksplorasi. Prosiding Seminar Nasional Geologi Nuklir dan Sumber Daya Tambang. Pusat Teknologi Bahan Galian Nuklir - BATAN.
Eurachem. (2014). The fitness for purpose of analytical methods: A laboratory guide to method validation and related topics (2nd edition). Europe.
FDA (Food and Drug Administration). (2001). Guidance for industry: Bioanalytical method validation. U.S. Department of Health and Human Services.
Fleming, I., & Williams, D.H. (1996). Spectroscopic Methods in Organic Chemistry. New York: McGraw-Hill.
Harmita. (2004). Petunjuk pelaksanaan validasi metode dan cara perhitungannya. Majalah Ilmu Kefarmasian, 1(3), 117-135.
Downloads
Published
How to Cite
Issue
Section
License
Copyright (c) 2025 Nian Tana Sikka : Jurnal ilmiah Mahasiswa

This work is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.